Universal rubber sheathed cable YC/YZ/YCW

Universal rubber sheathed cable YC/YZ/YCW is suitable for communication of household appliances and various mobile electrical equipment with extra voltage of 450/750V and below. First, the implementation of standards: JB8735.2-1998 

Second, the rubber cable use of characteristics 1, additional voltage 300/500V (YZ type), 450 / 750V (YC) type; 2, the core of the long-term promised working temperature should not exceed 65 ° C; 

3, “W” cable has weather resistance and certain oil resistance, suitable for outdoor or touch oil pollution; 

4, – ZR  rubber cable has flame retardant function. 

3. Type, Universal rubber sheathed cable YC/YZ/YCW title and main purpose (see Table 1)     

Types of title The main purpose
YQ, YQW Light rubber flexible cable For light mobile equipment and things
YZ, YZW Medium rubber flexible cable Used in a variety of mobile electrical equipment and things flat ribbon cable
YC, YCW Heavy duty rubber sheathed flexible cable Used in a variety of mobile electrical equipment, Marine cable can accept the effect of large mechanical external force

Fourth, Universal rubber sheathed cable YC/YZ/YCW standard size (see Table 2)

Types of  Extra voltage (V) Number of cores Nominal cross section (mm2)
YQ, YQW 300/300 2,3 0.3 to 0.5
YZ, YZW 300/500 2,3,4,5 0.75~6
YC, YCW 450/750

3,4 
5
1.5~240 
1.5~95 
1.5~150 
1.5~25

V. Universal rubber sheathed cable YC/YZ/YCW Standard scale and technical parameters such as (see Table 3 to Table 5) 
Table 3 YQ, YQW type 300/300V High temperature cable

Nominal cross section (mm2) Conductor layout Conductor resistance ≤ (Ω / km) at 20 ° C Cable outer diameter reference (mm)
Root / single wire diameter mm 2 core 3-core silicone rubber cable
0.3 16/0.15 69.2 6.6
0.5 28/0.15 39.0 silicone wire 7.2  high temperature flexible silicone cable

Universal rubber sheathed cable YC/YZ/YCW Table 4 YZ, YZW type 300/500V Heat Trace Cable

Nominal cross section (mm2) Conductor layout Conductor resistance ≤ (Ω / km) at 20 ° C Cable outer diameter reference (mm) k type thermocouple
Root / single wire diameter mm 2 core 3-core 4-core 5-core 3+1 core
0.75 24/0.20 26.0 8.2 8.8 9.6 11.0
1.0 32/0.20 19.5 8.8 9.2 10.0 11.5
1.5 30/0.25 13.3 10.5 11.0 12.5 13.5 12.0
2.5 49/0.25 7.98 12.5 13.0 14.0 15.5 14.0
4 56/0.30 4.95 14.0 14.5 16.5 18.0 16.0
6 84/0.30 3.30 17.0 18.0 20.0 22.5 19.5

Universal rubber sheathed cable YC/YZ/YCW Table 5 YZ, YZW type 300/500V

Nominal cross section (mm2) Conductor layout Conductor resistance ≤ (Ω / km) at 20 ° C Cable outer diameter reference (mm)
Root / single wire diameter mm 1 core 2 core 3-core 4-core 5-core 3+1 core
1.5 30/0.25 13.3 7.2 11.5 12.5 15.5 15.0
2.5 49/0.25 7.98 8.0 13.5 14.5 16.5 17.0 15.5
4 56/0.30 4.95 9.0 15.0 16.0 18.0 19.5 17.5
6 84/0.30 3.30 11.0 18.5 20.0 22.0 24.5 21.0
10 84/0.40 1.91 13.0 24.0 25.5 28.0 31.0 26.5
16 126/0.40 1.21 14.5 27.5 29.5 32.0 35.5 30.5
25 196/0.40 0.780 16.5 31.5 34.0 37.5 41.5 35.5
35 276/0.40 0.554 18.5 35.5 38.0 42.0 38.5
50 396/0.40 0.386 21.0 41.0 43.5 48.5 46.0
70 360/0.50 0.272 24.0 46.0 49.5 55.0 51.0
95 475/0.50 0.206 26.0 50.5 54.0 60.5 55.0
120 608/0.25 0.161 28.5 59.0 65.5 59.0
150 756/0.50 0.129 32.0 66.5 74.0 66.0
185 925/0.50 0.106 34.5
240 1221/0.50 0.0801 38.0

Universal rubber sheathed cable YC/YZ/YCW  delivery requirements 1, into a circle of 100M, the disk should be greater than 100M; 2, short-term cable is not less than 10M, the delivery of short-term cable does not exceed the total length of delivery 10%, and each package should not exceed Five paragraphs; 3, according to the two sides agreement to allow any length of cable delivery, length error is ± 0.5%; 4, the user has flame retardant characteristics of the product, in the contract need to supplement the agreement.   