YQ YZ YC universal rubber cable

I. YQ YZ YC universal rubber cable Production Implementation Standards: JB8735.2-1998
II. Anhui Tiankang (Group)Shares Co., Ltd Usage Characteristics of Rubber Sheathed Cables
1. The rated voltage is 300/500V (YZ type) and 450/750V (YC type).
2. flat ribbon cable The long-term allowable working temperature of the core shall not exceed 65 C.
3. “W” cable has weather resistance and oil resistance, which is suitable for outdoor or oil contamination occasions.4. – shielded ribbon cable ZR cable has flame retardant performance.
3. YQ YZ YC universal rubber cable Type, Name and Main Uses of Rubber Sheathed Cables Table 1

YQ YZ YC universal rubber cable Table 1

marine electric wire Model Name Main uses
YQ, YQW yqw Equipment and tools for light mobile appliances
YZ, YZW Medium Rubber Flexible Cable Used for various mobile electrical equipment and tools
YC, YCW ycw Used in all kinds of mobile electrical equipment, can withstand the role of greater mechanical external force
  1. YQ YZ YC universal rubber cable Specification scope as shown in Table 2

Table 2

Model Oil resistant heavy duty rubber cable Rated voltage (V) Core number Nominal cross section (mm2)
YQ, YQW 300/300 23 0.3~ 0.5
YZ, YZW 300/500 23, 4, 5 0.75~ 6
YC, YCW 450/750 1
2
345
1.5240 1.5-95 1.5-150 1.5-25
  1. YQ YZ YC universal rubber cable Specifications, dimensions and technical parameters as shown in Table 3-Table 5

Table 3 YQ, YQW 300/300V high temperature cable

Nominal cross section (mm2) Conductor structure Conductor resistance (/km) at 20 C Cable Outer Diameter Reference (mm)
Root/single line diameter mm 2core 3core
0.3 16/0.15 69.2 6.6 7.0
0.5 28/0.15 39.0 7.2 7.6

YQ YZ YC universal rubber cable Table 4 YZ, YZW 300/500V PUR polyurethane cable

Nominal cross section (mm2) Conductor structure Conductor resistance (/km) at 20 C Cable Outer Diameter Reference (mm)
Root/single line diameter mm 2core 3core 4core 5core 3+1core
0.75 24/0.20 26.0 8.2 8.8 9.6 11.0
1.0 32/0.20 19.5 8.8 9.2 10.0 11.5
1.5 30/0.25 13.3 10.5 11.0 12.5 13.5 12.0
2.5 49/0.25 7.98 12.5 13.0 14.0 15.5 14.0
4 56/0.30 4.95 14.0 14.5 16.5 18.0 16.0
6 84/0.30 3.30 17.0 18.0 20.0 22.5 19.5

YQ YZ YC universal rubber cable Table 5 YZ, YZW 300/500V

outdoor rated rs485 cable Nominal cross section (mm2) Conductor structure Conductor resistance (/km) at 20 C Cable Outer Diameter Reference (mm)
Root/single line diameter mm 1core 2core 3core 4core 5core 3+1core
1.5 30/0.25 13.3 7.2 11.5 12.5 15.5 15.0
2.5 49/0.25 7.98 8.0 13.5 14.5 16.5 17.0 15.5
4 56/0.30 4.95 9.0 15.0 16.0 18.0 19.5 17.5
6 84/0.30 3.30 11.0 18.5 20.0 22.0 24.5 21.0
10 84/0.40 1.91 13.0 24.0 25.5 28.0 31.0 26.5
16 126/0.40 1.21 14.5 27.5 29.5 32.0 35.5 30.5
25 196/0.40 0.780 16.5 31.5 34.0 37.5 41.5 35.5
35 276/0.40 0.554 18.5 35.5 38.0 42.0 38.5
50 396/0.40 0.386 21.0 41.0 43.5 48.5 46.0
70 360/0.50 0.272 24.0 46.0 49.5 55.0 51.0
95 475/0.50 0.206 26.0 50.5 54.0 60.5 55.0
120 608/0.25 0.161 28.5 59.0 65.5 59.0
150 756/0.50 0.129 32.0 66.5 74.0 66.0
185 925/0.50 0.106 34.5
240 1221/0.50 0.0801 38.0
  1. YQ YZ YC universal rubber cable Delivery Requirements
  2. When the circle is 100M, the circle should be more than 100M.
  3. Short-segment cables shall not be less than 10M, self regulating heat trace cable and the quantity of short-segment cables shall not exceed 10% of the total length of delivery, and each package shall not exceed five segments Mining power cable.
  4. Thermocouple compensation cable Delivery of cable of any length is allowed according to the agreement between the two parties, and the length error is (+0.5%).
  5. Users have requirements for flame retardant properties of products, and heat-resistant multicore cable additional agreements are required in the contract.

Leave a Reply